August 3, 2009 at 10:25 am
I am using a script component within a dataflow. In the preExecute sub I am trying to reference a variable using the format :
dts.variables("VarName").value.tostring
This same format works fine in a Script Task. The namespaces between the Task and Component are the same. The only difference is in the Script Task there is a reference to sqlserver.ScriptTask. There is no reference available for script component. I don't think this has anything to do with variable references.
The component is setup as a destination.
Namespaces:
Imports System
Imports System.Data
Imports System.Math
Imports Microsoft.SqlServer.Dts.Pipeline.Wrapper
Imports Microsoft.SqlServer.Dts.Runtime.Wrapper
Imports System.Xml
Imports Microsoft.SqlServer.Dts.Runtime
Error:
Name "dts" not declared
I'm looking for the correct method to reference a package variable in a Script Component.
August 3, 2009 at 4:59 pm
Try this:
Me.ReadOnlyVariables("varname").Value
You will also need to add the variable to the ReadOnlyVariables or ReadWriteVariables in the Script Component properties of course.
August 3, 2009 at 5:50 pm
Thanks that did the trick!